Home About us Editorial board Search Browse articles Submit article Instructions Contacts Login 
Users Online: 887
Home Print this page Email this page

 

ORIGINAL ARTICLE
Year : 2019  |  Volume : 8  |  Issue : 1  |  Page : 223

Competency in home body fat monitoring by portable devices based on bioelectrical impedance analysis: A pilot study


1 Department of Physiology, Fakir Mohan Medical College and Hospital, Balasore, Odisha, India
2 Department of Physiology, Kalna SD Hospital, Kalna, West Bengal, India
3 Department of Surgery, JB Roy State Ayurvedic Medical College and Hospital, Kolkata, West Bengal, India

Correspondence Address:
Dr. Shaikat Mondal
Department of Physiology, Kalna SD Hospital, Kalna - 713 409, West Bengal
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jehp.jehp_358_18

Rights and Permissions

INTRODUCTION: With the advancement of bioelectrical impedance analysis method, body fat can be estimated with portable devices at home. These devices are popular in home body fat monitoring (HBFM). However, improper use of the device may provide erroneous result. AIM: This study aimed to find out the level of competency of the operator in HBFM. MATERIALS AND METHODS: A cross-sectional survey was conducted with 34 individuals (males = 11, females = 23) during March–December, 2017. A pretested questionnaire was used to collect information by expert interviewer. Data were collected about premeasurement precautions, steps followed in body fat measurement proper, and postmeasurement action. Survey data were expressed in mean, standard deviation, and percentage and statistically tested by unpaired t-test and Chi-square test according to necessity with α =0.05. Analyses were done in GraphPad Prism 6.01. RESULTS: Premeasurement precautions for maintaining proper hydration level were not followed by majority of the participants. Avoidance of exercise in preceding 12 h was not followed by 94.12% (χ2 = 26.47, P < 0.0001), voiding bladder before the measurement was not followed by 88.24% (χ2 = 19.88, P < 0.0001), and avoidance of diuretics (e.g., chocolate, caffeine) was not practiced by 82.35% (χ2 = 14.24, P = 0.0002). Prescribed steps for measurement proper were followed by majority of the operators. However, 61.76% (χ2 = 1.88, P = 0.17) forgot to keep log of the readings. CONCLUSION: Clinicians, fitness instructors, and nutritionists should emphasize on premeasurement factors for educating their clients for HBFM. This would help proper tracking of body fat level.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed40    
    Printed0    
    Emailed0    
    PDF Downloaded9    
    Comments [Add]    

Recommend this journal