CASE REPORT
J Edu Health Promot 2018,  7:168

Rehabilitation of ocular defect: A modified technique to produce corneal prominence


Department of Prosthodontics and Implantology, Saraswati Dental College and Hospital, Lucknow, Uttar Pradesh, India

Date of Submission10-Jul-2018
Date of Acceptance08-Sep-2018
Date of Web Publication28-Dec-2018

Correspondence Address:
Dr. Sumit Kumar Misra
Department of Prosthodontics and Implantology, Saraswati Dental College and Hospital, Lucknow - 227 105, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jehp.jehp_213_18

Rights and Permissions
  Abstract 

Esthetics is a vital social concern. The loss of any part of the body can be an extremely discouraging occasion in a person's life. Loss of an eye because of tumors, congenital abnormalities, and trauma is one such troublesome situation. Eye prosthesis boosts the morale and makes the life socially acceptable. A correctly placed ocular prosthesis should reestablish the normal opening of the eye, support the eyelids, reestablish a degree of movement, and be satisfactorily held and esthetically satisfying. A customized acrylic eye fulfills all these requirements. In the current article, a new and economic technique was used to duplicate corneal prominence using a clear acrylic shell. The characterization was further done to give a life-like appearance to the eye prostheses.

Keywords: Esthetics, eye movement, ocular prosthesis, prosthodontics


How to cite this article:
Misra SK, Chopra D, Srivastava S. Rehabilitation of ocular defect: A modified technique to produce corneal prominence. J Edu Health Promot 2018;7:168

How to cite this URL:
Misra SK, Chopra D, Srivastava S. Rehabilitation of ocular defect: A modified technique to produce corneal prominence. J Edu Health Promot [serial online] 2018 [cited 2019 Mar 18];7:168. Available from: http://www.jehp.net/text.asp?2018/7/1/168/248922


  Introduction Top


Inherent disfigurements, tumors, and procured traumatic lesions of an eye may prompt enucleation or evisceration.[1] The loss of an eye can be a very distressing event in a person's life, both medically and emotionally. Physical deformity often compromises appearance or function, which affects the person's day-to-day life. This usually pushes the individual to pursue treatment that will reinstall the normalcy of life.[2] Eye prosthesis boosts the morale and makes the life socially acceptable.[2],[3] The stock acrylic resin eyes were manufactured to meet the increasing demand. The fitting of stock eyes was quite fast, but the results were not satisfactory.[4] A customized acrylic resin artificial eye has turned out to be the most attractive and satisfactory esthetic substitution. Following case report illustrates a novel technique to duplicate the corneal prominence and iris using iris button and rehabilitation of ocular defect.


  Case Report Top


A 58-year-old male patient reported to the Department of Prosthodontics, Saraswati Dental College, Lucknow, with an enucleated left eye. The patient lost his eye after an incident of chicken pox at the age of 6 years. The enucleated socket was inspected to determine the depth and degree of mobility of the socket [Figure 1]a. It was decided to rehabilitate the patient with a custom-made ocular prosthesis for a better fit, retention, and esthetics. The treatment procedures were explained to the patient before the commencement of the procedures, and informed consent was obtained.
Figure 1: (a) Patient with ocular defect. (b) Primary impression of the socket with alginate. (c) Secondary impression with polyether. (d) Split cast with wax pattern. (e) Wax pattern trial with determination of location of iris. (f) Putty index of iris button. (g) Dupliation of coroneal prominenece using clear acrylic auto polymerizing resin. (h) Wax pattern with corneal prominence. (i) Investing of wax pattern in the crown flask. (j) Finished ocular prosthesis with characterization. (k) Patient with finished ocular prosthesis in place

Click here to view


Procedure

The patient was instructed to look straight ahead at a preselected object. Primary impression was made using ophthalmic alginate loaded into a 5-ml disposable syringe (without needle) [Figure 1]b. Cast was poured over this impression and custom tray was fabricated. Escape vents were made on the custom tray and the hub of the disposable syringe was attached over it. With custom tray in position, polyether impression material was injected, and the patient was instructed to make eye movement [Figure 1]c. The impression was taken out, and two-piece split cast mold was poured [Figure 1]d.

Wax pattern was fabricated on the split cast and tried into the clinical defect. The wax pattern was modified to duplicate the shape of the natural eye. The eyelid drape of both eyes was matched after placing the wax pattern. The position of the iris was decided according to the contralateral natural eye. An adhesive tape was adhered over the forehead of the patient. The patient was asked to look straight, and a midline was marked over the tape. A second marking was made to mark the middle of the pupil. The distance between these two marked lines was measured and transferred on the defect size to locate the position of iris over the wax pattern [Figure 1]e.

Fabrication of iris part

The iris button was used to duplicate the iris with autopolymerizing clear acrylic resin. A putty index of iris button was made using heavy-body elastomeric impression material [Figure 1]f. The index was lined with a thin layer of autopolymerizing resin. Once the resin was set, the pattern was taken out [Figure 1]g. A digital photograph of contralateral eye was taken and printed over a glossy photo paper. The iris portion from the photo was cut and was placed over the resin pattern. It was covered with cyanoacrylate to make it impermeable to fluids. This complete iris portion was now placed and adjusted, creating a space over the wax pattern on the location determined by the markings made on the forehead of the patient [Figure 1]h. The symmetry and location of the iris were checked by asking the patient to perform eye movement in different directions. This step motivated the patient and inculcated confidence in him.

Processing of ocular prosthesis

The wax pattern was invested in a small flask (crown flask) and dewaxing was done in the conventional manner [Figure 1]i. To improve the characterization (e.g., simulation of the blood vessels) of the ocular prosthesis, acrylic threads/fibers were separated from the veined heat cure material [Figure 1]j (Trevalon HI, Dentsply). The mold was packed with preselected shade of tooth-colored heat-cure polymerizing resin (DPI, India). Long curing cycle of 4–6 h was used for acrylization.

After the retrieval of prosthesis, finishing was done. Once the fit was checked, polishing was done to give it a glossy appearance. Prosthesis was disinfected and was then finally placed into the socket. Postinsertion instructions were given to the patient [Figure 1]k. Follow-up was done after 1 week. The patient was satisfied with the fit and appearance of eye prosthesis.


  Discussion Top


With the advancement in dental materials, the socket can be finely recorded on which custom-made ocular prosthesis can be created with exact fit and esthetics.[4] Impression making is a vital procedure during the creation of ocular prosthesis. The literature depicts different procedure such as utilization of stock tray with alginate for stock impression and a custom tray with elastomeric impression material for the final impression.[4],[5],[6],[7],[8] The custom tray depends on the patient's existing anatomy and thus results in intimate adaptation of the eye prostheses to enucleated socket.[9],[10] Intimate adaptation of ocular prosthesis increases the movement of prosthesis and complements its natural appearance.[2]

Till now, the iris button was used as a corneal prominence. In such cases, every time a new iris button was needed, this added to the cost of procedure. In the current article, the iris button was duplicated in the form of a thin shell using clear acrylic resin. The putty index made to duplicate it can be used every time to produce corneal prominence shell, eliminating the use of new iris buttons. The characterization of eye prosthesis gave a life-like appearance enhancing the overall esthetics. The use of rayon thread fibrils was used to simulate vasculature, by monomer-polymer syrup method.[10] In this case report, to save time, acrylic threads/fibers were separated from the veined heat-cure material (Trevalon “HI”, Dentsply).


  Conclusion Top


This case report depicts a novel system to duplicate the corneal prominence and iris utilizing iris button and restoration of the ocular defect. Characterization of the ocular prosthesis was another viewpoint that necessities more discourse. Such prosthesis provides extraordinary psychological advantage and reestablishes the cosmetic appearance of the patient.

Acknowledgment

I would like to extend my sincere gratitude to coauthors of this case report, Dr. Devendra Chopra and Dr. Sudhanshu Srivastava for their constant efforts and contribution. A special thanks to my wife Dr. Nisha Sharma, my junior colleague Dr. Abhishek Jain and Dr. Dharmendra Sinha for their continuous support during the preparation of this article.

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient has given his consent for his images and other clinical information to be reported in the journal. The patient understands that name and initials will not be published and due efforts will be made to conceal identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
  References Top

1.
Burner J, Curtis TA, Firtell DN. Maxillofacial Rehabilitation: Prosthodontic and Surgical Considerations. St. Louis: CV Mosby Co.;1974.  Back to cited text no. 1
    
2.
Taicher S, Steinberg HM, Tubiana I, Sela M. Modified stock-eye ocular prosthesis. J Prosthet Dent 1985;54:95-8.  Back to cited text no. 2
    
3.
Sykes LM. Custom made ocular prostheses: A clinical report. J Prosthet Dent 1996;75:1-3.  Back to cited text no. 3
    
4.
Welden RB, Niiranen JV. Ocular prosthesis. J Prosthet Dent 1956;6:272-8.  Back to cited text no. 4
    
5.
Cain JR. Custom ocular prosthetics. J Prosthet Dent 1982;48:690-4.  Back to cited text no. 5
    
6.
Doshi PJ, Aruna B. Prosthetic management of patient with ocular defect. J Indian Prosthodont Soc 2005;5:37-8.  Back to cited text no. 6
  [Full text]  
7.
Allen L, Webster HE. Modified impression method of artificial eye fitting. Am J Ophthalmol 1969;67:189-218.  Back to cited text no. 7
    
8.
Bartlett SO, Moore DJ. Ocular prosthesis: A physiologic system. J Prosthet Dent 1973;29:450-9.  Back to cited text no. 8
    
9.
Mathews MF, Smith RM, Sutton AJ, Hudson R. The ocular impression: A review of the literature and presentation of an alternate technique. J Prosthodont 2000;9:210-6.  Back to cited text no. 9
    
10.
Taylor TD. Clinical Maxillofacial Prosthetics. Chicago: Quintessence Publishing; 2000. p. 233-76.  Back to cited text no. 10
    


    Figures

  [Figure 1]



 

Top
Previous article  Next article
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Case Report
Discussion
Conclusion
References
Article Figures

 Article Access Statistics
    Viewed164    
    Printed16    
    Emailed0    
    PDF Downloaded23    
    Comments [Add]    

Recommend this journal